Trauma patient came in to the ED:

CXR 1

What’s Wrong With This Picture?

The patient’s chest tube is not inserted far enough.  It is also a bit high residing between ribs 3-4.

Chest tubes have a side port and a distal port for suctioning fluids, air from the pleural space.  There is a radiopaque line seen on the tube that is interrupted at the side port (see magnified image).  In this case the radiograph shows that the side port is subcutaneous and not inserted all the way into the pleural space.  The chest tube needs to be replaced!

Author:  Russell Jones, MD

Image Contributor:  David Barnes, MD